LINETRAXX® VMD460-NA

  • Network and system protection with default basic programs for national standards and regulations
  • Interface RS-485 (data exchange/parameter setting)
  • Continuous monitoring of the phase voltage and line-to-line voltage
  • Remote shutdown via ripple control signal receiver

The VMD460-NA is an external network and system protection (NS protection) the purpose of which is to disconnect the power generation system from the grid by coupling switches in the event of inadmissible threshold values. If voltage and frequency measurements on the power generation system are outside the thresholds required in the standards, the relays of the VMD460-NA will switch. The VMD460-NA is multifunctionally adjustable.

The currently measured values are continuously shown on the LC display. The measured values leading to the tripping of the relays are stored.

Questions? Contact us!

LINETRAXX® VMD460-NA
LINETRAXX® VMD460-NA
  • Network and system protection with default basic programs for national standards and regulations
  • Interface RS-485 (data exchange/parameter setting)
  • Continuous monitoring of the phase voltage and line-to-line voltage
  • Remote shutdown via ripple control signal receiver

The VMD460-NA is an external network and system protection (NS protection) the purpose of which is to disconnect the power generation system from the grid by coupling switches in the event of inadmissible threshold values. If voltage and frequency measurements on the power generation system are outside the thresholds required in the standards, the relays of the VMD460-NA will switch. The VMD460-NA is multifunctionally adjustable.

The currently measured values are continuously shown on the LC display. The measured values leading to the tripping of the relays are stored.

Questions? Contact us!

Features

  • Straightforward commissioning due to pre-set basic programs for national standards and regulations
    NEW: G99/1-4:2019
    NEW: G98/1-4:2019
  • Single-fault tolerance
  • Monitoring of the connected coupling switch (configurable: NC/NO/off)
  • Islanding detection df/dt (ROCOF)
  • Vector shift
  • Interface RS-485 (data exchange, parameter setting)
  • Test function for the determination of the disconnection time
  • Test button for the trigger circuit
  • The last 300 distribution network faults can be recalled with time stamp/real-time clock
  • Continuous monitoring of the phase and line-to-line voltage
  • Separate switching conditions after a threshold infringement
  • Language selection (German, English, Italian)
  • Backlit graphics LC display
  • Remote shutdown via ripple control signal receiver
  • Password protection for device setting
  • Sealable enclosure

Applications

Application examples

  • Central NS protection (VDE-AR-N 4105)
  • Protective disconnection (VDE-AR-N 4110, BDEW)
  • Interface Protection (IP) (Engineering Recommendations; EREC G99, G59, G83, G59)
  • Protezione di interfaccia (CEI 0-21)
  • Automatic disconnection device between a generating plant parallel to the network
  • and the public network
  • Universal for generating plants for safe network decouplingg

Approvals/certificates of conformity/manufacturer declarations

  • VDE-AR-N 4105:2018-11
  • VDE-AR-N 4105:2011-08
  • VDE-AR-N 4110:2018-11
  • BDEW technical guideline 2008 incl. amendments until 01.2013
  • G99/1:2019
  • G59/2
  • G59/3
  • G98/1:2019
  • G83/2
  • CEI 0-21 (:2012-06, :V1:2012-12, :V2:2013-12, :2014-09, :V1:2014-12, :2016-07, V1:2017-07)
  • C10/11:2012-06
  • DIN V VDE V 0126-1-1(:2016-06, /A1:2012-02)

LINETRAXX® VMD460-NA Variant(s)

TypeSupply voltage USArt. No.
VMD460-NA-D-2AC/DC 100…240 VB93010045

Downloads for LINETRAXX® VMD460-NA

NameCategorySizeLanguageTimestampD-/B-Number
UKCA - VMD460 Declarations of Conformity 121.2 KB 2022/12/2020.12.2022
VMD460 CE Declarations of Conformity 82.9 KB 2022/08/1212.08.2022
Certificate of compliance VMD460-NA G83/2 Declarations of Conformity 392.0 KB EN2019/05/1313.05.2019D00001
Certificate of compliance VMD460-NA G59/3 Declarations of Conformity 373.6 KB EN2019/05/1313.05.2019D00001
Certificate of compliance VMD460-NA G59/2 Declarations of Conformity 227.4 KB EN2019/05/1313.05.2019D00001
Certificate of compliance VMD460-NA C10/11 Declarations of Conformity 347.1 KB EN2019/05/1313.05.2019D00001
VMD460-NA Quickstarts 988.7 KB EN2021/07/1313.07.2021D00001
VMD460-NA Manuals 7.0 MB EN2022/06/0909.06.2022D00001
VMD460-NA Datasheets 523.7 KB EN2021/07/1313.07.2021D00001
Certificate of compliance VMD460-NA G98-1 Declarations of Conformity 549.1 KB EN2019/11/0505.11.2019
Certificate of compliance VMD460-NA G99-1 Declarations of Conformity 557.5 KB EN2020/12/0808.12.2020